The PowerLogic P5 range includes dedicated solutions for voltage, feeder, transformer, motor and line protection, allowing engineers and project buyers to select the appropriate relay according to the protection scheme and system configuration.
Why Choose Schneider PowerLogic P5?
Multifunction Protection & Control
Integrates protection, automation, control and monitoring for demanding power distribution projects.
Optional Arc-Flash Protection
P5x30 supports up to 6 point arc-flash sensor inputs for fast fault detection and isolation.
Advanced Cybersecurity
IEC 62443-4-2 Security Level 1 certified for secure digital power system integration.
Flexible Communication
Supports IEC 61850, Modbus, DNP3, IEC 60870 and EtherNet/IP for project system integration.
Withdrawable Design
Easy replacement and backup memory help reduce maintenance and system downtime.
Wireless Condition Monitoring
Supports TH110 and CL110 wireless sensors for switchgear thermal and environmental monitoring.

PowerLogic P5 Model Selection
| Application | Model | Description |
|---|---|---|
| Voltage | P5V20 | - |
| Feeder | P5U20 | With directional in LPCT/LPVT version |
| Feeder | P5F30 | With directional |
| Transformer | P5T30 | - |
| Motor | P5M30 | With directional |
| Line | P5L30 | With directional |
| Characteristic | P5V20 | P5U20 | P5F30 / P5M30 / P5L30 | P5T30 |
|---|---|---|---|---|
| Phase Current | - | 1/5A CT (x3) or LPCT (x3) (1) | 1/5A CT (x3) or LPCT (x3) | 1/5A CT (x6) |
| Residual Current | - | 1/5A CT & 1A CT or CSH core balance CT | 1/5A CT & 1A CT or CSH core balance CT | 1/5A CT (x2) |
| Voltage | VT (x4) | LPVT (x4) (1) | VT (x4) or LPVT (x4) | VT (x1) |
| Arc-Flash Sensor Inputs | - | - | 0 to 6 point sensors | 0 to 6 point sensors |
| Characteristic | P5V20 | P5U20 | PowerLogic P5x30 |
|---|---|---|---|
| Digital Inputs | 4 to 16 | 4 to 16 | 4 to 40 |
| Outputs | 3 to 8 + Watchdog (WD) | 3 to 8 + Watchdog (WD) | 3 to 18 + Watchdog (WD) |
| Temperature Sensor Input | - | 0 to 16 (external modules) | 0 to 16 (external modules) |
| Analogue Inputs / Outputs | 0 to 12/12 (external modules) | 0 to 12/12 (external modules) | 0 to 12/12 (external modules) |
| Front Ports | 1 USB for configuration; 1 USB for USB key | 1 USB for configuration; 1 USB for USB key | 1 USB for configuration; 1 USB for USB key |
| Power Supply | 24-250 VDC ; 100-230 VAC | 24-250 VDC ; 100-230 VAC | 24 - 48 VDC or 48-250 VDC ; 100-230 VAC |
| Ambient Temperature, In Service | -40 to 70 °C (-40 to 158 °F) | -40 to 70 °C (-40 to 158 °F) | -40 to 70 °C (-40 to 158 °F) |
| Series | Width / Height / Depth |
|---|---|
| PowerLogic P5x20 | 102 / 176 / 219 mm |
| PowerLogic P5x20 | 4.01 / 6.93 / 8.62 in |
| PowerLogic P5x30 | 152 / 176 / 219 mm |
| PowerLogic P5x30 | 6.0 / 6.93 / 8.62 in |
| No. | Note |
|---|---|
| (1) | In case P5U20 is chosen for cooperation with low power sensors, it contains LPCT (x3) and LPVT (x4) channels. |
| (2) | For connection of RTD module and IRIG-B module. |
| (3) | IRIG-B module is a separate accessory. |
| (4) | PTP IEEE 1588 v2 is available with HSR/PRP communication board. |
| (5) | P5L30 is not available with LPCT/LPVT inputs. |

PowerLogic P5 has been developed as a protection and control relay for demanding applications and combines advanced protection functionality with communication, monitoring and maintainability.
Key advantages include:
To select the correct Schneider PowerLogic P5 protection relay, please provide:
Send us your project BOM, single-line diagram or existing Schneider model number for model confirmation and quotation.

What we can do ?
We partner with world-class manufacturers including Schneider, ABB, Siemens, Omron, Eaton, Rittal, Sick, WIKA, Weidmuller, Fuji, Chint and Delixi to deliver stable, customized power and automation solutions for clients across over 50 countries worldwide.
Our comprehensive service portfolio covers overseas commercial & industrial power distribution EPC, data center power supply systems, commercial PV & energy storage, new energy storage box-type substations, petrochemical automatic measurement systems, special power solutions for marine & mining, as well as energy-saving industrial variable frequency drive solutions. We integrate top-tier brand components and professional system design to cut energy consumption, improve operational stability and lower overall project costs for global industrial and commercial enterprises.


Funator (Suzhou Funator Industrial Co., Ltd.) is the exclusive overseas trade platform of HEJI GROUP, specializing in power transformers, industrial automation equipment, electrical equipment and electronic components for global B2B customers.
Backed by HEJI GROUP's industrial network of 43+ controlled subsidiaries, 1,800+ employees and 15 warehouses across China, we provide reliable supply, competitive lead times and professional project support. Our key products include power transformers, solid state transformers (SST), MV/LV electrical equipment and industrial automation solutions.
OEM & ODM customization, technical selection, project coordination and export delivery support are available for global industrial and power projects.

No. PowerLogic P5 is a protection and control relay designed for demanding electrical protection applications. It is intended for project applications involving feeder, transformer, motor, line or voltage protection rather than ordinary control-relay applications.
The P5 range includes P5U20 and P5F30 feeder protection configurations. P5F30 includes directional functionality, while P5U20 provides directional functionality in its LPCT/LPVT version.
P5T30 is the dedicated transformer protection configuration in the PowerLogic P5 range.
Yes. P5M30 is the dedicated motor protection configuration and includes directional functionality.
Yes. Both P5x20 and P5x30 support IEC 61850 Edition 1 and Edition 2.
Yes. Supported protocols include Modbus Ethernet, Modbus Serial, DNP3 Ethernet and DNP3 Serial.
P5x30 configurations support 0 to 6 point arc-flash sensor inputs. Arc-flash protection is an optional protection function depending on the selected configuration.
The P5 supports RSTP and PRP / HSR redundancy protocols. P5x30 also provides support for a second Ethernet or InterRelay connection.
PowerLogic P5 can provide wireless thermal and environmental condition monitoring when connected with compatible PowerLogic TH110 and CL110 wireless sensors.
Send us your:
Model / BOM / Single-Line Diagram / Protection Requirements / Quantity
Our team can assist with model confirmation, configuration checking, project quotation and delivery schedule confirmation before order placement.
Request a Project Quotation Now.
If you have any questions, please contact us!